Article in English | LILACS-Express | LILACS | ID: biblio-1385842

ABSTRACT

ABSTRACT: The aim of this study was to evaluate the influence of overtorque on integrity, strength and stress on external hexagonal implants (EH), with two different grades (N=10): conventional (C), grade 4; and modified (M), grade 4 with thermal treatment. The dimensions of EH were 3.75 x 13 mm; the specimens were fixed and submitted to SEM analysis and image acquisition. The abutment was then retained with 70 N/cm, re-analyzed by SEM, and a second image was obtained. The images were analyzed by Image J software (1.44o- NIH, USA) for dimensional variations measurement on surface of the hexagonal area. The finite element method was applied with a similar compliance to calculate the resultant stress (MPa) during the torque. Results were statistically analyzed with t-student test (5 %). The dimensional accuracy of M (0.22 mm2) was statistically significant (p<0.05). Minimum principal stress and von-Mises stress of C (-19.95 MPa, -19.94 MPa), were lower than M values (-55.83 MPa, -55.96 MPa), respectively. However, the M group showed lower deformation than C group. Therefore, more rigid titanium alloy is a promising alternative to avoid plastic deformation of prosthetic connec tions even concentrating higher stress magnitude on its structure.


RESUMEN: El objetivo de este estudio fue evaluar la influencia del sobrepar en la integridad, la fuerza y la tensión en los implantes hexagonales externos (EH), con dos grados diferentes (N = 10): convencional (C), grado 4; y modificado (M), grado 4 con tratamiento térmico. Las dimensiones de EH eran 3,75 de diámetro x 13 mm de longitud; las muestras se fijaron y se sometieron a análisis SEM y adquisición de imágenes. A continuación, el pilar se retuvo con 70 N / cm, se volvió a analizar por SEM y se obtuvo una segunda imagen. Las imágenes se analizaron con el software Image J (1.44o-NIH, EE. UU.) Para medir las variaciones dimensionales en la superficie superior del área hexagonal, que fue causada por un par excesivo. El método de los elementos finitos se aplicó con un cumplimiento similar para calcular la tensión resultante (MPa) durante el par. Los resultados se analizaron estadísticamente con la prueba t-student (5 %). La precisión dimensional de M (0,22 mm2) fue estadísticamente significativa (p <0,05). La tensión principal mínima y la tensión de von-Mises de C (-19,95 MPa, -19,94 MPa), fueron inferiores a los valores de M (-55,83 MPa, -55,96 MPa), respectivamente. Sin embargo, el hexágono del grupo M mostró menor deformación que el grupo C. Por lo tanto, la aleación de titanio más rígida es una alternativa prometedora para evitar la deformación plástica de las conexiones protésicas incluso concentrando una mayor magnitud de tensión en su estructura.

2.
São José dos Campos; s.n; 2016. 81 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-870230

ABSTRACT

Este trabalho teve por objetivo avaliar o efeito do filme de carbono (DLC) aplicado por plasma como recobrimento da liga de Ti -6Al-4V e do polietileno de alto peso molecular (UHMWPE) em prótese totais de ATM, com a finalidade de melhorar suas propriedades bio-tribológicas. Outro aspecto abordado neste trabalho a aplicação do planejamento virtual utilizando a técnica de elementos finitos (FEA), na apresentação de um caso clínico, colocando a importância do cirurgião de conhecer a fundo tanto o planejamento cirúrgico quanto o desenvolvimento da prótese customizadas (TMJ), e assim evitar possíveis falhas biomecânicas. Material: Para o desenvolvimento deste trabalho primeiramente foram utilizados 40 corpos de prova de Ti-6Al-V, dos quais 15 foram recobertas com um DLC e 15 por DLC-Ag pelo método de deposição químico (PECVD), e 10 foram mantidos sem recobrimento como controle. Além disso, foram confeccionados 30 corpos de prova de UHMWPE, dos quais, 15 foram recobertas por DLC pelo sistema de deposição físico (CVD) e 15 foram mantidas sem recobrimento como controle. Métodos: Foram avaliadas as características superficiais das amostras, adesão em simulador de fadiga deslizante reproduzindo o trabalho condili fossapo 2000,000 de ciclos em banho com ringuer lactato a 36 graus, a uma carga 200 N. As amostras com filmes foram submetidas a teste de citotoxicidade com células osteoblásticas. Resultados: As células se mostraram uma biocompatibilidade significativa com as amostras portando filme de DLC em substrato Ti6Al4v, se mostrando inerte ao polietileno. Neste estudo também foi apresentado um caso clinico, paciente com 12 anos de idade genero feminino, portadora de anquilose bilateral da ATM relatou já ter sido submetida a cirurgias repetidas sem sucesso, apresentando deformidade esqueletal classe II, em consequência da anquilose temporomandibular,abertura bucal limitada inicial (4,9 mm) e pós cirúrgico reconstrução bilateral com prótese total de ATM...


This study aimed to evaluate the effect of carbon film (DLC) applied by plasma ascoating the Ti-6Al-4V alloy and ultra high molecular weight polyethylene(UHMWPE) in total TMJ prosthesis, in order to improve their bio-tribologicalproperties. Another aspects addressed in this work are the application of virtualplanning using the technique of finite element (FEA) and the presentation of a case, placing the importance of the surgeon to know the background both surgical planning and the development of customized prosthesis (TMJ) and thus avoid possible biomechanical faults. Material: For the development of this work were first used 40 specimens of Ti-6Al-V, of which 15 were coated with a DLC and 15 DLC-Ag by chemical deposition method (PECVD), and 10 were kept without coating as control. In addition, they made 30 UHMWPE specimens, of which 15 were coated with DLC by physical deposition system (CVD) and 15 were maintained without coating as a control. Methods: The surface characteristics of the samples were evaluated for adhesion sliding fatigue tester reproducing the work condili fossapo 2000.000 cycles in banhocom ringuer lactate at 36 degrees,to a load 200 N. The film samples were subjected to cytotoxicity testing inosteoblastic cells. Results: The cells showed a significant biocompatibility with samples carrying DLC film on Ti6Al4V substrate, showing inert to thepolyethylene. This study also presented a clinical case patient with 12 years offemale gender age, bearer of bilateral ankylosis of the TMJ reported having been subjected to repeated unsuccessful attempts, with deformity skeletal class II, as a result of temporomandibular ankylosis, limited mouth opening initial (4.9 mm) and post surgical bilateral reconstruction with customized ATM denture after surgery, showed up with an opening (23 mm) after one year, with a significant improvement for food and severe sleep apnea. Conclusion: Dlc titanium within the parameterswe can deposition, is presented...


Subject(s)
Joint Prosthesis , Nanotechnology , Temporomandibular Joint Disorders , Oral Surgical Procedures
3.
São José dos Campos; s.n; 2016. 81 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867707

ABSTRACT

Este trabalho teve por objetivo avaliar o efeito do filme de carbono (DLC) aplicado por plasma como recobrimento da liga de Ti -6Al-4V e do polietileno de alto peso molecular (UHMWPE) em prótese totais de ATM, com a finalidade de melhorar suas propriedades bio-tribológicas. Outro aspecto abordado neste trabalho a aplicação do planejamento virtual utilizando a técnica de elementos finitos (FEA), na apresentação de um caso clínico, colocando a importância do cirurgião de conhecer a fundo tanto o planejamento cirúrgico quanto o desenvolvimento da prótese customizadas (TMJ), e assim evitar possíveis falhas biomecânicas. Material: Para o desenvolvimento deste trabalho primeiramente foram utilizados 40 corpos de prova de Ti-6Al-V, dos quais 15 foram recobertas com um DLC e 15 por DLC-Ag pelo método de deposição químico (PECVD), e 10 foram mantidos sem recobrimento como controle. Além disso, foram confeccionados 30 corpos de prova de UHMWPE, dos quais, 15 foram recobertas por DLC pelo sistema de deposição físico (CVD) e 15 foram mantidas sem recobrimento como controle. Métodos: Foram avaliadas as características superficiais das amostras, adesão em simulador de fadiga deslizante reproduzindo o trabalho condili fossapo 2000,000 de ciclos em banho com ringuer lactato a 36 graus, a uma carga 200 N. As amostras com filmes foram submetidas a teste de citotoxicidade com células osteoblásticas. Resultados: As células se mostraram uma biocompatibilidade significativa com as amostras portando filme de DLC em substrato Ti6Al4v, se mostrando inerte ao polietileno. Neste estudo também foi apresentado um caso clinico, paciente com 12 anos de idade genero feminino, portadora de anquilose bilateral da ATM relatou já ter sido submetida a cirurgias repetidas sem sucesso, apresentando deformidade esqueletal classe II, em consequência da anquilose temporomandibular,abertura bucal limitada inicial (4,9 mm) e pós cirúrgico reconstrução bilateral com prótese total de ATM ...


This study aimed to evaluate the effect of carbon film (DLC) applied by plasma ascoating the Ti-6Al-4V alloy and ultra high molecular weight polyethylene(UHMWPE) in total TMJ prosthesis, in order to improve their bio-tribologicalproperties. Another aspects addressed in this work are the application of virtualplanning using the technique of finite element (FEA) and the presentation of a case, placing the importance of the surgeon to know the background both surgical planning and the development of customized prosthesis (TMJ) and thus avoid possible biomechanical faults. Material: For the development of this work were first used 40 specimens of Ti-6Al-V, of which 15 were coated with a DLC and 15 DLC-Ag by chemical deposition method (PECVD), and 10 were kept without coating as control. In addition, they made 30 UHMWPE specimens, of which 15 were coated with DLC by physical deposition system (CVD) and 15 were maintained without coating as a control. Methods: The surface characteristics of the samples were evaluated for adhesion sliding fatigue tester reproducing the work condili fossapo 2000.000 cycles in banhocom ringuer lactate at 36 degrees,to a load 200 N. The film samples were subjected to cytotoxicity testing inosteoblastic cells. Results: The cells showed a significant biocompatibility with samples carrying DLC film on Ti6Al4V substrate, showing inert to thepolyethylene. This study also presented a clinical case patient with 12 years offemale gender age, bearer of bilateral ankylosis of the TMJ reported having been subjected to repeated unsuccessful attempts, with deformity skeletal class II, as a result of temporomandibular ankylosis, limited mouth opening initial (4.9 mm) and post surgical bilateral reconstruction with customized ATM denture after surgery, showed up with an opening (23 mm) after one year, with a significant improvement for food and severe sleep apnea. Conclusion: Dlc titanium within the parameterswe can deposition, is presented..


Subject(s)
Joint Prosthesis , Nanotechnology , Temporomandibular Joint Disorders , Oral Surgical Procedures
4.
PróteseNews ; 2(4): 460-469, out.-dez. 2015. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-846766

ABSTRACT

O objetivo deste estudo foi relatar um caso clínico no qual foi utilizado o sistema KEA-TECH, para planejamento e confecção do guia tomográfi co/cirúrgico na colocação de implante cone-morse com carga imediata. Foi proposta ao paciente (sexo masculino, 69 anos), com fratura radicular do elemento 11, a utilização da coroa natural remanescente como elemento provisório imediato. Pôde-se concluir que o planejamento adequado garante sucesso na reabilitação com implantes em áreas estéticas. Além disso, a utilização do sistema KEA-TECH proporciona facilidade e rapidez nos procedimentos clínicos.


The aim of this study was to report a clinical case where the KEA-TECH system was used to plan the tomographic/surgical guide and place a morse cone implant for immediate loading. The male, 69 years-old patient presented a root fracture at tooth 11, and his natural crown was used as a provisional immediate restoration. It was demonstrated that the adequate planning guarantees the success of implant rehabilitation in esthetic areas. Besides, the use of the KEA-TECH system allows for an easier and speed procedure at the daily clinics.


Subject(s)
Humans , Male , Aged , Dental Implantation/methods , Immediate Dental Implant Loading , Patient Care Planning , Prostheses and Implants , Surgery, Computer-Assisted
5.
Fisioter. mov ; 20(3): 123-130, jul.-set. 2007. tab
Article in English | LILACS | ID: lil-487002

ABSTRACT

Este artigo tem por objetivo analisar a atividade elétrica dos músculos massteres por meio da eletromiografia de superfície (EMG) e a eficiência das placas miorrelaxantes em mulheres portadoras de bruxismo do sono (BS). SB foi definido por suas características clínicas. Para o estudo da EMG de superfície, um sistema de registro dos sinais foi utilizado e eletrodos bipolares de prata de 10mm de diãmetro foram posicionados sobre os pontos motores dos músculos. A coleta dos sianis foi realizada na posição de oclusão mandibular sem apertar e registrou recepção dos sinais dos músculos masseteres em todos os indivíduos após um dia normal de trabalho sem utilização de placas miorrelaxantes; e, a segunda, após uma noite de sono com o uso de placas miorrelaxantes em ambos os lados. Os mesmos resultados foram verificados na posição de máxima contração voluntária. Esses resultados confirmam que o uso de placas miorrelaxantes em mulheres portadoras de bruxismo do sono reduz a atividade mioelétrica dos masseteres esquerdo e direito, mostrnado seu efeito miorrelaxante


Este artigo tem por objetivo analisar a atividade elétrica dos músculos masseteres por meio da eletromiografia de superfície (EMG) e a eficiência das placas miorrelaxantes em mulheres portadoras de bruxismo do sono (BS). SB foi definido por suas características clínicas. Para o estudo da EMG de superfície, um sistema de registro dos sinais foi utilizado e eletrodos bipolares de prata de 10 mm de diâmetro foram posicionados sobre os pontos motores dos músculos. A coleta dos sinais foi realizada na posição de oclusão mandibular sem apertar e na posição de máxima contração voluntária em duas situações distintas. A primeira coleta registrou recepção dos sinais dos músculos masseteres em todos os indivíduos após um dia normal de trabalho sem utilização de placas miorrelaxantes; e, a segunda, após uma noite de sono com o uso de placas miorrelaxantes. Avaliando os músculos masseteres durante a oclusão mandibular sem apertamento, foi observado que valores menores dos sinais EMG foram encontrados após o uso de placas miorrelaxantes em ambos os lados. Os mesmos resultados foram verificados na posição de máxima contração voluntária. Esses resultados confirmam que o uso de placas miorrelaxantes em mulheres portadoras de bruxismo do sono reduz a atividade mioelétrica dos masseteres esquerdo e direito, mostrando seu efeito miorrelaxante.


Subject(s)
Humans , Female , Electromyography , Masseter Muscle , Occlusal Splints , Sleep Bruxism , Women
6.
Rev. ABO nac ; 14(2): 117-122, abr.-maio 2006. tab
Article in Portuguese | LILACS, BBO | ID: lil-462926

ABSTRACT

O uso de filogenia molecular sem a necessidade de cultura permitiu aos pesquisadores da área odontológica constatar que os biofilmes orais são comunidades microbianas com maior diversidade de bactérias do que se acreditava. Recentemente, estudos estatísticos relacionaram saúde oral precária a doenças sistêmicas e outras investigações demonstraram que alguns dos componentes da microbiota oral podem causar moléstias sistêmicas. Estes componentes podem ser tanto patógenos periodontais bem conhecidos, apresentando a capacidade de promover lesões em outros tecidos humanos; quanto bactérias oportunistas que também colonizam o biofilme. As alternativas clínicas para minimizar estes problemas incluem a promoção da saúde oral em populações específicas. Já as abordagens em pesquisa incluem os estudos em nível molecular, proporcionando uma grande sensibilidade na detecção de microrganismos e conhecimento mais abrangente sobre os mecanismos de interação entre as bactérias orais e o hospedeiro. O objetivo deste artigo é discutir o papel das bactérias orais nas doenças sistêmicas e os diferentes desafios para os pesquisadores nesse campo>